Large Range >800 kVA
P1375-1
KEY SPECS
Minimum Rating
1250 kVA / 1000 kW
Maximum Rating
1375 kVA / 1100 kW
Emissions/Fuel Strategy
Fuel Optimised
Overview
730 - 2500 kVA Range
Proven in the field, this range of generator sets are capable of providing reliable power for critical applications including: mini power stations, data centres, large factories, airports, hospitals, large retail stores, and the financial sector. A 50oC package option is available to ensure efficient operation in high ambient temperatures. Custom-built weatherproof and acoustic enclosures can be tailored to suit any application. Providing personnel access and separate components for cooling, they make generator set installation and maintenance as quick and easy as possible.
Benefits
Up To 2000L Extended
Capacity Fuel Tanks
Larger fuel tanks allow for longer periods of time between refueling
As Low As 57 dBA Super silent enclosures
Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m
Telematics Ready Stay In
Control Telematics Ready
Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m
Product Specifications
Minimum Rating 1250 kVA / 1000 kW
Maximum Rating 1375 kVA / 1100 kW
Emissions/Fuel Strategy Fuel Optimised
50 Hz Prime 1250 kVA / 1000 kW
50 Hz Standby 1375 kVA / 1100 kW
60 Hz Prime – I –
60 Hz Standby __
Frequency 50 / 60 Hz
Speed 1500 / 1800 RPM
Voltage 220-420 Volts
50 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1hour in 12 hours.
60 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating
Standard reference conditions 2S♦C (77♦F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Specifications
Engine Model Perkins® 1106A-70TAG4
Bore 105 mm (3 in)
Stroke 135 mm (5.3 in)
Governor Type Mechanical
Displacement 7.0l (427.8 cu. in)
Compression Ratio 19.23:01
Small Range <220 Kva P7.5-1S
Minimum Rating
6.8 kVA / 6.8 kW
Minimum Rating
7.5 kVA / 7.5 kW
Emissions/Fuel Strategy
Fuel Optimised
Small Range <220 Kva P7.5-4S
Minimum Rating
6.8 kVA / 6.8 kW
Minimum Rating
8.8 kVA / 8.8 kW
Emissions/Fuel Strategy
EUIIIa Emissions Compliant
Small Range <220 Kva P9.5-1
Minimum Rating
8.5 kVA / 6.8 kW
Minimum Rating
9.5 kVA / 7.6 kW
Fuel Optimized
800 kVA / 640 kW
Small Range <220 Kva P9.5-4
Minimum Rating
8.5 kVA / 6.8 kW
Minimum Rating
11 kVA / 8.8 kW
Emissions/Fuel Strategy
EUIIIa Emissions Compliant