PEGC Power Solutions

Small Range <220 Kva

P90-6S

KEY SPECS

Minimum Rating

82 kVA / 82 kW

Maximum Rating

90 kVA / 90 kW

Emissions/Fuel Strategy

EU Stage IIIA emissions compliant.

Overview

6.8 - 25 kVA

The 6.8 – 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Benefits

Up To 2000L Extended
Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Telematics Ready Stay In
Control Telematics Ready

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Product Specifications

Minimum Rating                                82 kVA / 82 kW

Maximum Rating                                90 kVA / 90 kW

Emissions/Fuel Strategy                   EU Stage IIIA emissions compliant.

50 Hz Prime                                        82 kVA / 82 kW

50 Hz Standby                                    90 kVA / 90 kW

60 Hz Prime                                        I

60 Hz Standby                                      __

Frequency                                          50 Hz

Speed                                                  1500 RPM

Voltage                                               230-415 Volts

50 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1hour in 12 hours.

60 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

50 Hz Standby Rating

Standard reference conditions 2S♦C (77♦F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

Engine Specifications

 

Engine Model                         Perkins® 1104D-E44TAG2

Bore                                         105 mm (3 in)

Stroke                                     127 mm (3.9 in)

Governor Type                       Mechanical

Displacement                         4.4l (69 cu. in)

Compression Ratio                16.2:01 

Small Range <220 Kva P7.5-1S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

7.5 kVA / 7.5 kW

Emissions/Fuel Strategy

Fuel Optimised

Small Range <220 Kva P7.5-4S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

8.8 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant

Small Range <220 Kva P9.5-1

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

9.5 kVA / 7.6 kW

Fuel Optimized

800 kVA / 640 kW

Small Range <220 Kva P9.5-4

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

11 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant

Scroll to Top