Small Range <220 Kva
P110-6
KEY SPECS
Minimum Rating
100 kVA / 80 kW
Maximum Rating
110 kVA / 88 kW
Emissions/Fuel Strategy
EU Stage IIIA emissions compliant.
Overview
6.8 - 25 kVA
The 6.8 – 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.
Benefits
Up To 2000L Extended
Capacity Fuel Tanks
Larger fuel tanks allow for longer periods of time between refueling
As Low As 57 dBA Super silent enclosures
Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m
Telematics Ready Stay In
Control Telematics Ready
Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m
Product Specifications
Minimum Rating 100 kVA / 80 kW
Maximum Rating 110 kVA / 88 kW
Emissions/Fuel Strategy Fuel Optimised
50 Hz Prime 100 kVA / 80 kW
50 Hz Standby 110 kVA / 88 kW
60 Hz Prime – I –
60 Hz Standby __
Frequency 50 Hz
Speed 1500 RPM
Voltage 230-415 Volts
50 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1hour in 12 hours.
60 Hz Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating
Standard reference conditions 2S♦C (77♦F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Specifications
Engine Model Perkins® 1104D-44TG2/3
Bore 105 mm (3 in)
Stroke 127 mm (3.9 in)
Governor Type Mechanical
Displacement 4.4l (69 cu. in)
Compression Ratio 18.23:01
Small Range <220 Kva P7.5-1S
Minimum Rating
6.8 kVA / 6.8 kW
Minimum Rating
7.5 kVA / 7.5 kW
Emissions/Fuel Strategy
Fuel Optimised
Small Range <220 Kva P7.5-4S
Minimum Rating
6.8 kVA / 6.8 kW
Minimum Rating
8.8 kVA / 8.8 kW
Emissions/Fuel Strategy
EUIIIa Emissions Compliant
Small Range <220 Kva P9.5-1
Minimum Rating
8.5 kVA / 6.8 kW
Minimum Rating
9.5 kVA / 7.6 kW
Fuel Optimized
800 kVA / 640 kW
Small Range <220 Kva P9.5-4
Minimum Rating
8.5 kVA / 6.8 kW
Minimum Rating
11 kVA / 8.8 kW
Emissions/Fuel Strategy
EUIIIa Emissions Compliant