PEGC Power Solutions

Large Range >800 kVA

P1375-1

KEY SPECS

Minimum Rating

1250 kVA / 1000 kW

Maximum Rating

1375 kVA / 1100 kW

Emissions/Fuel Strategy

Fuel Optimised

Overview

730 - 2500 kVA Range

Proven in the field, this range of generator sets are capable of providing reliable power for critical applications including: mini power stations, data centres, large factories, airports, hospitals, large retail stores, and the financial sector. A 50oC package option is available to ensure efficient operation in high ambient temperatures. Custom-built weatherproof and acoustic enclosures can be tailored to suit any application. Providing personnel access and separate components for cooling, they make generator set installation and maintenance as quick and easy as possible.

Benefits

Up To 2000L Extended
Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Telematics Ready Stay In
Control Telematics Ready

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Product Specifications

Minimum Rating                                1250 kVA / 1000 kW

Maximum Rating                               1375 kVA / 1100 kW

Emissions/Fuel Strategy                  Fuel Optimised

50 Hz Prime                                        1250 kVA / 1000 kW

50 Hz Standby                                    1375 kVA / 1100 kW

60 Hz Prime                                        I

60 Hz Standby                                      __

Frequency                                          50 / 60 Hz

Speed                                                  1500 / 1800 RPM

Voltage                                               220-420 Volts

50 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1hour in 12 hours.

60 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

50 Hz Standby Rating

Standard reference conditions 2S♦C (77♦F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Engine Specifications

 

Engine Model                        Perkins® 1106A-70TAG4

Bore                                         105 mm (3 in)

Stroke                                     135 mm (5.3 in)

Governor Type                       Mechanical

Displacement                         7.0l (427.8 cu. in)

Compression Ratio                19.23:01 

Small Range <220 Kva P7.5-1S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

7.5 kVA / 7.5 kW

Emissions/Fuel Strategy

Fuel Optimised

Small Range <220 Kva P7.5-4S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

8.8 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant

Small Range <220 Kva P9.5-1

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

9.5 kVA / 7.6 kW

Fuel Optimized

800 kVA / 640 kW

Small Range <220 Kva P9.5-4

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

11 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant

Scroll to Top