PEGC Power Solutions

Small Range <220 Kva

P12-1S

KEY SPECS

Minimum Rating

11 kVA / 11 kW

Maximum Rating

12 kVA / 12 kW

Emissions/Fuel Strategy

Fuel Optimised

Overview

6.8 - 25 kVA

The 6.8 – 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Benefits

Up To 2000L Extended
Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Telematics Ready Stay In
Control Telematics Ready

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Product Specifications

Minimum Rating                                11 kVA / 11 kW

Maximum Rating                               12 kVA / 12 kW

Emissions/Fuel Strategy                    Fuel Optimised

50 Hz Prime                                        11 kVA / 11 kW

50 Hz Standby                                    12 kVA / 12 kW

60 Hz Prime                                        I

60 Hz Standby                                      __

Frequency                                          50 Hz

Speed                                                  1500 RPM

Voltage                                               220-240 Volts

50 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1hour in 12 hours.

60 Hz Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

50 Hz Standby Rating

Standard reference conditions 2S♦C (77♦F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.12 kVA / 12 kW

 

Engine Specifications

Engine Model                        Perkins® 403A-11G1

Bore                                        84 mm (3 in)

Stroke                                     90 mm (3.2 in)

Governor Type                       Mechanical

Displacement                         1.5L (91.3 cu. in)

Compression Ratio                22.5:01

Small Range <220 Kva P7.5-1S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

7.5 kVA / 7.5 kW

Emissions/Fuel Strategy

Fuel Optimised

Small Range <220 Kva P7.5-4S

Minimum Rating

6.8 kVA / 6.8 kW

Minimum Rating

8.8 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant

Small Range <220 Kva P9.5-1

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

9.5 kVA / 7.6 kW

Fuel Optimized

800 kVA / 640 kW

Small Range <220 Kva P9.5-4

Minimum Rating

8.5 kVA / 6.8 kW

Minimum Rating

11 kVA / 8.8 kW

Emissions/Fuel Strategy

EUIIIa Emissions Compliant